Description of Operation
The LANCNC-FAD acts as an FTP server for file storage that in turn can be accessed by
a Fadal CNC. Connection to the FTP server can be done with standard software tools that
are provided with most PC’s. A logon is not required as the LANCNC FTP server
accepts anonymous logins. Special software is not required. The most popular of these
are Explorer and Internet Explorer from Microsoft. Anyone on the network can drag and
drop files to the CNC server where they can be transferred to machine memory or drip
fed (DNC). Conversely, files residing in CNC memory can be sent to the data server
where they can be accessed by anyone on the network.
File information is stored on an SD card resident on the LANCNC-FAD. A 1 GB or
greater SD card is provided as standard. Other sizes may be substituted. In the event of a
network outage, the SD card may be removed and inserted into a PC. Files can be added
or stored at the PC and replaced in the LANCNC-FAD.
Note: Files should follow the 8.3 format for proper operation. E.g. File name should not
exceed 8 characters and the suffix should not exceed 3 characters.
The operator interface to the data server on the CNC side is done on the pendant of the
Fadal CNC. Special ‘+’ commands are used to active the data server on the CNC side.
The correct CD,# must be used for proper operation.
The CNC command CD,8 sets a baud rate of 9600 to the LANCNC-FAD.
The CNC command CD,10 sets a baud rate of 38400 to the LANCNC-FAD.
The CNC command CD,11 sets a baud rate of 57600 to the LANCNC-FAD.
(The above assumes that the version of Fadal control supports the baud rates listed.)
Once a CD command is entered, a LANCNC-FAD plus command may be used. A plus
command activates the LANCNC-FAD device and allows it to take control of the CNC
machine. When the command is finished, the LANCNC-FAD will issue a BYE command
to the machine. Another CD,# will be needed before another plus command can be sent
to the LANCNC-FAD device. The following demonstrates the order of operation to
execute a LANCNC-FAD command:
1. Enter the CD, Change Device, command for the LANCNC-FAD connected to
machine (example: CD,10 CD,11 or CD,8).
2. Type in the LANCNC-FAD command desired, ending the entry with a + sign and
not a carriage return (enter key).
3. Wait for command to be processed (a couple of seconds if a SD card has just
inserted).
4. Command is finished after the BYE command.