OmniView
IP*
KVM Tech Sheet 0005
51xxK Series (part numbers F1DP101M, F1DP108G, F1DP116G)
52xxK Series (part numbers F1DP216G, F1DP232G)
This document covers the process of restoring factory defaults.
Contents
51xxKSeries ............................................................................................................................................................................ 1
52xxKSeries ............................................................................................................................................................................ 2
51xxKSeries
In order to restore your KVM switch to factory defaults without using the web interface, follow the steps below:
Step 1
Press and hold down the “Go-Local” button on the back of the IP Device for five seconds while powering it up.
The IP Device will boot up in safe mode.
Step 2
Wait 30 seconds for the IP Device to reboot.
Step 3
If a DHCP server is available, the IP Device will pick up an IP address from it. If there is no DHCP server, the
IP Device will boot with a static IP address: 192.168.2.155.
Step 4
Log in with the default IP address of the unit: http://192.168.2.155/config. The blank login screen will appear
(no background picture).
Note:
Do not start the IP address with https.
Step 5
Type in the following default user name and password (case-sensitive), and click “Login”. This user name and
password only work immediately after the reset procedure described above.
Safe-Mode User
Safe-Mode
Password
admin SAFEmode
Step 6
From the menu, select “Restore Factory Settings”. A warning will appear advising you that all device data will